Applicable gases:
liquefied petroleum gas, natural gas
Service pressure:
5KPa
Environmental temperature:
-20~+60 °C (without icing)
Drive power supply:
solenoid valve DC24V; Proportional valve 100~250mA (DC superimposed AC constant current source)
Rated power:
below 25W (at 20 °C)
Insulation level:
Class B (130 °C)
External leakage:
≤ 35mL/hi, intake pressure 15KPa)
Internal leakage:
≤ 35mL/hi, intake pressure 5KPa)
Setting direction:
The air inlet is vertically downward, with a inclination angle of within 5 °
Connection terminal:
solenoid valve AMP187. Proportional valve AMP187
Description:
The voltage of the solenoid valve can be selected as 24V, 110V, or 220V