Product
product
TPV1D2408F
Applicable gases: liquefied petroleum gas, natural gas
Service pressure: 5KPa
Environmental temperature: -20~+60 °C (without icing)
Drive power supply: solenoid valve DC24V; Proportional valve 100~250mA (DC superimposed AC constant current source)
Rated power: below 25W (at 20 °C)
Insulation level: Class B (130 °C)
External leakage: ≤ 35mL/hi, intake pressure 15KPa)
Internal leakage: ≤ 35mL/hi, intake pressure 5KPa)
Setting direction: The air inlet is vertically downward, with a inclination angle of within 5 °
Connection terminal: solenoid valve AMP187. Proportional valve AMP187
Description: The voltage of the solenoid valve can be selected as 24V, 110V, or 220V
Product Structure(Wiring diagram)
img
Characteristic Curve
img
Physical Dimension
img